Difference between revisions of "Fusion Transformer"

From Fusion Registry Wiki
Jump to navigation Jump to search
(Error Codes)
(Return Codes)
 
(23 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
[[Category:Functions]]
 +
[[Category:How_To]]
 
=Overview=
 
=Overview=
The Fusion Transformer is a command line application providing transformations between SDMX, and EDI structure files and data ???  files.
+
The Fusion Transformer is a command line application providing transformations between supported data files.
  
 
'''The following structure file formats are supported:'''<br>
 
'''The following structure file formats are supported:'''<br>
Line 38: Line 40:
  
 
The Structure Transformer can be run by executing the command:
 
The Structure Transformer can be run by executing the command:
 +
 +
java -cp FusionTransformer.jar io.sdmx.fusion.dataparser.StructureParseMain
 +
 +
'''Note:''' on releases prior to version 2.2, the command is:
  
 
  java -cp FusionTransformer.jar org.bis.fusion.dataparser.StructureParseMain
 
  java -cp FusionTransformer.jar org.bis.fusion.dataparser.StructureParseMain
 
  
 
For convenience there is a structureTransform.bat file provided that Windows user can use to launch the main class.  
 
For convenience there is a structureTransform.bat file provided that Windows user can use to launch the main class.  
Line 58: Line 63:
 
| -edi_lenient || False || Puts the Transformer into EDI Lenient mode. || -No Arguments-
 
| -edi_lenient || False || Puts the Transformer into EDI Lenient mode. || -No Arguments-
 
|-
 
|-
| -o <arg> || False || Output file.
+
| -o <arg> || True|| Output file.
 
|-
 
|-
 
| -pretty_print || False || Outputs the SDMX-ML structures in a more readable format. || -No Arguments-
 
| -pretty_print || False || Outputs the SDMX-ML structures in a more readable format. || -No Arguments-
 
|-
 
|-
| -s <arg> || False || URI of structure file to transform. If this option is not specified or the argument is - then input is taken from Standard Input. ||   
+
| -s <arg> || True|| URI of structure file to transform. If this option is not specified or the argument is - then input is taken from Standard Input. ||   
  
 
If this option is not specified or the argument is - then output is sent to Standard Output. ||   
 
If this option is not specified or the argument is - then output is sent to Standard Output. ||   
Line 69: Line 74:
 
| -ug || False || If present will ‘upgrade group’ attributes in a SDMX v2.0 DSD to become a Dimension Group Attribute in v2.1. The Group will still be present in the DSD so the v2.1 Schema is backwards compatible with v2.0 (allowing data to be submitted as either a Group or Series level attribute). || -No Arguments-
 
| -ug || False || If present will ‘upgrade group’ attributes in a SDMX v2.0 DSD to become a Dimension Group Attribute in v2.1. The Group will still be present in the DSD so the v2.1 Schema is backwards compatible with v2.0 (allowing data to be submitted as either a Group or Series level attribute). || -No Arguments-
 
|-
 
|-
| -v <arg> || False || The output version. || edi / edi-lenient/ 1.0 / 2.0 / 2.1
+
| -v <arg> || True|| The output version. || edi / edi-lenient/ 1.0 / 2.0 / 2.1
  
 
|}
 
|}
Line 81: Line 86:
 
=Data Transformation=
 
=Data Transformation=
 
The Data Transformer can be run by executing the command:
 
The Data Transformer can be run by executing the command:
 +
 +
java -cp FusionTransformer.jar io.sdmx.fusion.dataparser.DataParserMain
 +
 +
'''Note:''' on releases prior to version 2.2, the command is:
  
 
  java -cp FusionTransformer.jar org.bis.fusion.dataparser.DataParserMain
 
  java -cp FusionTransformer.jar org.bis.fusion.dataparser.DataParserMain
Line 99: Line 108:
 
! Argument !! Mandatory !! Description !! Allowed Arguments
 
! Argument !! Mandatory !! Description !! Allowed Arguments
 
|-
 
|-
| -d <arg> || False || URI of data file to transform. If this option is not specified or the argument is - then input is taken from Standard Input. ||   
+
| -d <arg> || True || URI of data file to transform. If this option is not specified or the argument is - then input is taken from Standard Input. ||   
 
|-
 
|-
 
| -f <arg> || True || Output data format. || compact / generic /edi
 
| -f <arg> || True || Output data format. || compact / generic /edi
 
|-
 
|-
| -o <arg> || False || Output file. If this option is not specified or the argument is - then output is sent to Standard Output. ||   
+
| -o <arg> || True || Output file. If this option is not specified or the argument is - then output is sent to Standard Output. ||   
 
|-
 
|-
 
| -s <arg> || True|| URI of structure file with DSD. ||   
 
| -s <arg> || True|| URI of structure file with DSD. ||   
 
|-
 
|-
| -v <arg> || False || Output SDMX Version if appropriate. || 1.0 / 2.0 / 2.1
+
| -v <arg> || True || Output SDMX Version if appropriate. || 1.0 / 2.0 / 2.1
 
|-
 
|-
 
| -split || False || Output SDMX Version if appropriate. || -No Arguments-
 
| -split || False || Output SDMX Version if appropriate. || -No Arguments-
 
|-
 
|-
| -tf || False || Prevents the Time Format attribute from being output in SDMX-EDI. || -No Arguments-
+
| -edi_group_identifier || False || Allows setting the group id when reading an EDI data file. || Either * or the group name
 
|-
 
|-
 
| -edi_lenient || False || Puts the Transformer into EDI Lenient mode. || -No Arguments-
 
| -edi_lenient || False || Puts the Transformer into EDI Lenient mode. || -No Arguments-
 +
|-
 +
| -edi_tf_attr || False || Creates Time Format Series Attribute from edi input. || -No Arguments-
 
|-
 
|-
 
| -pretty_print || False|| Outputs the SDMX-ML structures in a clearer fashion. || -No Arguments-
 
| -pretty_print || False|| Outputs the SDMX-ML structures in a clearer fashion. || -No Arguments-
Line 120: Line 131:
 
|-
 
|-
 
| -character_mapping || False|| Enables character mapping mode. || -No Arguments-
 
| -character_mapping || False|| Enables character mapping mode. || -No Arguments-
|-
 
| -edi_tf_attr || False|| Creates the series attribute “Time Format” from an EDI input file. || -No Arguments-
 
 
|-
 
|-
 
|}
 
|}
  
 
=File Formats and Character Encoding=
 
=File Formats and Character Encoding=
The Fusion Transformer expects that all files supplied to it are encoded using the charset UTF-8, except for EDI files which are expected to be encoded using the charset ISO-8995-1. If you supply a file that is not explicitly encoded to the appropriate charset, the Fusion Transformer will make the assumption that it is encoded in the expected charset and attempt to decipher it using that charset.
+
The Fusion Transformer expects that all files supplied to it are encoded using the charset UTF-8, except for EDI files which are expected to be encoded using the charset ISO-8859-1. If you supply a file that is not explicitly encoded to the appropriate charset, the Fusion Transformer will make the assumption that it is encoded in the expected charset and attempt to decipher it using that charset.
  
All of the files generated by the Fusion Transformer will be encoded using the charset UTF-8, except for EDI files which will be encoded using the charset ISO-8995-1.
+
All of the files generated by the Fusion Transformer will be encoded using the charset UTF-8, except for EDI files which will be encoded using the charset ISO-8859-1.
  
 
If you experience the Fusion Transformer behaving strangely with certain characters, please check the encoding of your input files using an appropriate software tool.
 
If you experience the Fusion Transformer behaving strangely with certain characters, please check the encoding of your input files using an appropriate software tool.
Line 150: Line 159:
 
  # The effect of this file is that <br>
 
  # The effect of this file is that <br>
 
  # ; characters will be removed from the output <br>
 
  # ; characters will be removed from the output <br>
  # the " character will be replaced with the ' character # the @ character will be replaced by the phrase "at symbol"<br>
+
  # the " character will be replaced with the ' character<br>
 +
# the @ character will be replaced by the phrase "at symbol"<br>
 
   ;= <br>
 
   ;= <br>
 
  "=' <br>
 
  "=' <br>
Line 208: Line 218:
 
''Example''<br>
 
''Example''<br>
  
  structureTransform.bat -o ediStructreOut21.edi -s StructureOut21.xml -v edi_lenient
+
  structureTransform.bat -o ediStructureOut21.edi -s StructureOut21.xml -v edi_lenient
  structureTransform.bat -o ediStructreOut21.edi -s StructureOut21.xml -v edi -edi_lenient
+
  structureTransform.bat -o ediStructureOut21.edi -s StructureOut21.xml -v edi -edi_lenient
  
 
When running the <big>'''data transformer'''</big>, supply the parameter -edi_lenient.<br>
 
When running the <big>'''data transformer'''</big>, supply the parameter -edi_lenient.<br>
Line 217: Line 227:
 
  dataTransform.bat -d ediData.ges -s Structures.xml -f generic -edi_lenient -o genericData.xml
 
  dataTransform.bat -d ediData.ges -s Structures.xml -f generic -edi_lenient -o genericData.xml
  
=Error Codes=
+
=EDI Group Identifier=
 +
The EDI standard states that groups in an EDI file should conform to the Group Name of "Sibling" in a DSD. So transforming data with groups will result in the output stating the group name is "Sibling"
 +
 
 +
To override this behavious use the argument: -edi_group_identifier. This requires an argument which can either be an asterisk (*) or a specific group name.  Specifying an asterisk instructs the Transformer to use the group name as defined in the DSD.
 +
 
 +
''Example #1 - the Transformer will output the group name as specified by the DSD''
 +
 
 +
dataTransform.bat -d ediData.ges -s Structures.xml -f generic -edi_group_identifier "*"
 +
 
 +
''Example #2 - the Transformer will output the group name as supplied. In this case "NewGroupName"''
 +
 
 +
dataTransform.bat -d ediData.ges -s Structures.xml -f generic -edi_group_identifier NewGroupName
 +
 
 +
=Return Codes=
 
The following return codes are returned by the applications.
 
The following return codes are returned by the applications.
  
Line 273: Line 296:
 
| 14 || Character Mapping file has key longer than a single character – this is not permitted
 
| 14 || Character Mapping file has key longer than a single character – this is not permitted
 
|}
 
|}
 +
 +
 +
In the windows command prompt you can  use the command
 +
 +
echo %ERRORLEVEL%
 +
 +
This will display the Return Code.
 +
 +
=Change Logs=
 +
See [[Change_Log_Fusion_Transformer|Fusion Transformer - Change Logs]]

Latest revision as of 23:57, 10 September 2023

Overview

The Fusion Transformer is a command line application providing transformations between supported data files.

The following structure file formats are supported:

• SDMX-ML Structure 1.0

• SDMX-ML Structure 2.0

• SDMX-ML Structure 2.1

• EDI

• SDMX-JSON


The following data file formats are supported:

• SDMX- Generic 1.0

• SDMX- Generic 2.0

• SDMX- Generic 2.1

• SDMX- Compact 1.0

• SDMX- Compact 2.0

• SDMX- StructureSpecific 2.1

• EDI

• SDMX-JSON

• SDMX-CSV

Structure Transformation

The Structure Transformer can be run by executing the command:

java -cp FusionTransformer.jar io.sdmx.fusion.dataparser.StructureParseMain

Note: on releases prior to version 2.2, the command is:

java -cp FusionTransformer.jar org.bis.fusion.dataparser.StructureParseMain

For convenience there is a structureTransform.bat file provided that Windows user can use to launch the main class.

Example usage:

structureTransform.bat -o ediStructreOut21.edi -s StructureOut21.xml -v edi

For UNIX users there is an equivalent file: structureTransform.sh.

The following additional arguments are available:

Argument Mandatory Description Allowed Arguments
-edi_lenient False Puts the Transformer into EDI Lenient mode. -No Arguments-
-o <arg> True Output file.
-pretty_print False Outputs the SDMX-ML structures in a more readable format. -No Arguments-
-s <arg> True URI of structure file to transform. If this option is not specified or the argument is - then input is taken from Standard Input.

If this option is not specified or the argument is - then output is sent to Standard Output. ||

-ug False If present will ‘upgrade group’ attributes in a SDMX v2.0 DSD to become a Dimension Group Attribute in v2.1. The Group will still be present in the DSD so the v2.1 Schema is backwards compatible with v2.0 (allowing data to be submitted as either a Group or Series level attribute). -No Arguments-
-v <arg> True The output version. edi / edi-lenient/ 1.0 / 2.0 / 2.1

There are several options for the output version. Supplying the argument 1.0, 2.0 or 2.1 will result in the creation of an SDMX-ML file in the specified format. Supplying the argument EDI will create an EDI file if possible.

The output version argument “edi-lenient” will put Fusion Transformer into EDI Lenient mode.

Please refer to the Section EDI Leniency for more information regarding this feature.

Data Transformation

The Data Transformer can be run by executing the command:

java -cp FusionTransformer.jar io.sdmx.fusion.dataparser.DataParserMain

Note: on releases prior to version 2.2, the command is:

java -cp FusionTransformer.jar org.bis.fusion.dataparser.DataParserMain

For convenience there is a dataTransform.bat file provided that Windows users can use to launch the main class.

Example usage:

dataTransform.bat -d TestData/inputData.ges -s TestData/inputDSD.ges -o output.xml -f compact

For UNIX users there is an equivalent file: dataTransform.sh.


The following additional arguments are available:

Argument Mandatory Description Allowed Arguments
-d <arg> True URI of data file to transform. If this option is not specified or the argument is - then input is taken from Standard Input.
-f <arg> True Output data format. compact / generic /edi
-o <arg> True Output file. If this option is not specified or the argument is - then output is sent to Standard Output.
-s <arg> True URI of structure file with DSD.
-v <arg> True Output SDMX Version if appropriate. 1.0 / 2.0 / 2.1
-split False Output SDMX Version if appropriate. -No Arguments-
-edi_group_identifier False Allows setting the group id when reading an EDI data file. Either * or the group name
-edi_lenient False Puts the Transformer into EDI Lenient mode. -No Arguments-
-edi_tf_attr False Creates Time Format Series Attribute from edi input. -No Arguments-
-pretty_print False Outputs the SDMX-ML structures in a clearer fashion. -No Arguments-
-unify_monthly False Outputs SDMX-ML monthly data in the format YYYY-Mmm. -No Arguments-
-character_mapping False Enables character mapping mode. -No Arguments-

File Formats and Character Encoding

The Fusion Transformer expects that all files supplied to it are encoded using the charset UTF-8, except for EDI files which are expected to be encoded using the charset ISO-8859-1. If you supply a file that is not explicitly encoded to the appropriate charset, the Fusion Transformer will make the assumption that it is encoded in the expected charset and attempt to decipher it using that charset.

All of the files generated by the Fusion Transformer will be encoded using the charset UTF-8, except for EDI files which will be encoded using the charset ISO-8859-1.

If you experience the Fusion Transformer behaving strangely with certain characters, please check the encoding of your input files using an appropriate software tool.

Character Mapping

When the Fusion Transformer works on a data file, it is possible to map individual characters to alternative characters or a String. This may be useful when trying to get a simplified output (for example converting the character ‘ to the character ' ) or for trying to avoid XML characters being encoded (for example replacing the character “ with the character ' would prevent the quotes character being output as " )

To enable character mapping the following conditions must be met:

• The data transform operation must be supplied with the argument -character_mapping

• A file called “character_mapping.properties” must exist in the directory where Fusion Transformer is running from.

• This file must conform to the standard Java property file format. Each entry in the file has a key and a value separated by the equals sign. Each key may only be a single character long, whereas the value may be any length (including zero length to exclude certain characters from the output).

For performance reasons, Character Mapping only affects attribute fields. This is because otherwise the semantic meaning of the file would be lost.

An example of a legal character mapping file:

# Example of a Fusion Transformer Character Mapping File 
# The effect of this file is that
# ; characters will be removed from the output
# the " character will be replaced with the ' character
# the @ character will be replaced by the phrase "at symbol"
;=
"='
@=at symbol
# EOF

Time Format Series Attribute Creation

By default, reading an EDI data file does not convert the TIME_FORMAT into an attribute in the output data file, however an option exists in Fusion Transformer to perform this. To enable this behaviour the flag “edi_tf_attr” must be passed to the Fusion Transformer and the Data Structure must have a series attribute with the id of “TIME_FORMAT”.

If both of these conditions are met, then the EDI values are converted in the following manner:

Time Format EDI Value ISO Format
Yearly 602 / 702 P1Y
Half Yearly 604 / 704 P6M
Quarterly 608 / 708 P3M
Monthly 610 / 710 P1M
Weekly 616 / 716 P1W
Daily 101 / 102 P1D
Minutely 201 / 203 PT1M

EDI Leniency

Fusion Transformer may be run in “EDI Leniency” mode. When running in this mode certain aspects of EDI which are enforced by the EDI standard are ignored.

Structures

EDI does not permit a structure to reference another structure belonging to a different Agency. When running in EDI Leniency mode, this restriction is disabled and the structures will all be stated as belonging to the same agency. For example, a Data Structure Definition in Agency 1 if it refers to a Codelist in Agency 2 cannot strictly be converted into EDI since EDI cannot express that the DSD and Codelist are in different agencies. In EDI Leniency mode, the outputted EDI file would state that both are owned by Agency1.

The EDI standard does not support uncoded dimensions in a Data Structure. All dimensions must be explicitly coded. When running in EDI Leniency mode, Data Structures with uncoded dimensions may be read or written without an exception being thrown.

In EDI, a Codelist can only have an ID and code IDs of up to 18 characters in length. A concept scheme may only have concept IDs up to 18 characters in length. EDI Leniency mode disregards these restrictions.

Data

EDI enforces the following limits on a data file:

• The Observation Value is limited to a maximum of 15 characters

• The Observation Attribute “OBS_STATUS” is limited to a maximum of 35 characters

• The Observation Attribute “OBS_CONF” is limited to a maximum of 35 characters

• The Observation Attribute “OBS_PRE_BREAK” is limited to a maximum of 15 characters

When running in EDI Leniency mode, none of the above restrictions apply when reading or writing a data file.

Enabling EDI Leniency Mode

When running the structure transformer, either supply the output version (the -v flag) as “edi_lenient” (also edi-lenient is supported for backwards-compatibility) or supply the parameter: -edi_lenient.

Example

structureTransform.bat -o ediStructureOut21.edi -s StructureOut21.xml -v edi_lenient
structureTransform.bat -o ediStructureOut21.edi -s StructureOut21.xml -v edi -edi_lenient

When running the data transformer, supply the parameter -edi_lenient.

Example

dataTransform.bat -d ediData.ges -s Structures.xml -f generic -edi_lenient -o genericData.xml

EDI Group Identifier

The EDI standard states that groups in an EDI file should conform to the Group Name of "Sibling" in a DSD. So transforming data with groups will result in the output stating the group name is "Sibling"

To override this behavious use the argument: -edi_group_identifier. This requires an argument which can either be an asterisk (*) or a specific group name. Specifying an asterisk instructs the Transformer to use the group name as defined in the DSD.

Example #1 - the Transformer will output the group name as specified by the DSD

dataTransform.bat -d ediData.ges -s Structures.xml -f generic -edi_group_identifier "*"

Example #2 - the Transformer will output the group name as supplied. In this case "NewGroupName"

dataTransform.bat -d ediData.ges -s Structures.xml -f generic -edi_group_identifier NewGroupName

Return Codes

The following return codes are returned by the applications.

Structure Transformer

Return Code Meaning
0 Application completed successfully.
1 No arguments specified.
2 Illegal argument specified.
4 Structure file could not be found.
6 Illegal output data format specified.
7 Cannot write to output file.
10 Error during transformation.

Data Transformer

Return Code Meaning
0 Application completed successfully.
1 No arguments specified.
2 Illegal argument specified.
3 Data File could not be found.
4 Structure File could not be found.
5 Specified schema version incorrect.
6 Illegal output data format specified.
7 Cannot write to output file.
10 Error during transformation.
11 Character Mapping option specified but file could not be found
12 Error reading character mapping file
13 Character Mapping file has empty key – this is not permitted
14 Character Mapping file has key longer than a single character – this is not permitted


In the windows command prompt you can use the command

echo %ERRORLEVEL%

This will display the Return Code.

Change Logs

See Fusion Transformer - Change Logs