Difference between revisions of "Time Format Alternate Half Year"
(→Is Alternate Half-Format set) |
|||
Line 1: | Line 1: | ||
− | At ESCB level SDMX data exchanges, there is an agreement to use 'H' as the frequency value for | + | At ESCB level SDMX data exchanges, there is an agreement to use 'H' as the frequency value for semi-annual observations. This is specified via 'YYYY-H1' or 'YYYY-H2'. |
− | The Registry supports this | + | The Registry supports this with a system property. When this is enabled the Registry is in 'alternate half year' mode. Under this mode: |
− | * Frequency value 'H' means half-year (semiannual or semester) | + | * Frequency value 'H' means half-year (semiannual or semester) as does frequency value 'S'. They are interchangeable as input. |
− | + | * 'YYYY-S1' and 'YYYY-H1' are valid TIME_PERIOD formats for half-yearly observations. | |
− | * 'YYYY-S1' and 'YYYY-H1' are valid TIME_PERIOD formats for half-yearly observations | + | * Output will always be in the 'S' format (e.g. an input of 'YYYY-H1' will be converted to 'YYYY-S1'). This ensures that the output is correct to the SDMX specification. |
+ | * The hourly frequency is not supported. | ||
− | Alternate half year mode is controlled at system level on Registry start-up by setting the Java System variable "TF_ALTERNATE_HALF_YEAR" to "true". | + | 'Alternate half year' mode is controlled at system level on Registry start-up by setting the Java System variable "TF_ALTERNATE_HALF_YEAR" to "true". |
== Setting System Property == | == Setting System Property == |
Revision as of 00:04, 12 July 2023
At ESCB level SDMX data exchanges, there is an agreement to use 'H' as the frequency value for semi-annual observations. This is specified via 'YYYY-H1' or 'YYYY-H2'.
The Registry supports this with a system property. When this is enabled the Registry is in 'alternate half year' mode. Under this mode:
- Frequency value 'H' means half-year (semiannual or semester) as does frequency value 'S'. They are interchangeable as input.
- 'YYYY-S1' and 'YYYY-H1' are valid TIME_PERIOD formats for half-yearly observations.
- Output will always be in the 'S' format (e.g. an input of 'YYYY-H1' will be converted to 'YYYY-S1'). This ensures that the output is correct to the SDMX specification.
- The hourly frequency is not supported.
'Alternate half year' mode is controlled at system level on Registry start-up by setting the Java System variable "TF_ALTERNATE_HALF_YEAR" to "true".
Setting System Property
If using Apache Tomcat, it is recommended to set the value via JAVA_OPTS and using the setenv.bat or setenv.sh file:
SET JAVA_OPTS=-DTF_ALTERNATE_HALF_YEAR=true (For Windows systems)
export JAVA_OPTS=-DTF_ALTERNATE_HALF_YEAR=true (For Unix systems)
Different procedures may be required for other web application servers like JBoss.
Is Alternate Half-Year Format set?
On startup the Fusion Registry system log will report the following message:
2021-12-31 23:59:59.123 INFO main io.sdmx.core.fmr.application.FusionRegistryApplicationInitialiser - Using 'Alternate Half-Year' Setting
Active system properties can also be queried using the REST API which is detailed here.